| Style 1185 Insulated, Shielded and Jacketed Wire. |
|
| Rating |
80 deg C, 300 Vac, Horizontal flame. |
|
| Conductor |
30 AWG - 4/0 AWG solid or stranded round, tinned or bare copper. |
|
| Insulation |
PVC
30-16 AWG conductor size 15 mils min average 13 min minimum at any point
15-10 AWG 30 avg 27 min
9-8 AWG 45 avg 40 min
7-2 AWG 60 avg 54 min
1-4/0 AWG 80 avg 72 min |
|
| Assembly |
Insulated conductor w. required insulation, optional shield, required jacket, optional shield, optional jacket. |
|
| Shield |
Optional. |
|
| Jacket |
PVC
30-16 AWG conductor size 15 mils min average 12 mils min at any point
15-2 AWG 30 avg 24 min
1-4/0 AWG 45 avg 36 min
or lacquered braid |
|
| Misc. |
Outer Jacket optional, 15 mils minimum average, 12 mils minimum at any point. |
|
| Standard |
Appliance Wiring Material UL 758. |
|
| Marking |
General. |
|
| Use |